免费观看B站60帧的视频软件_一线二线三线99热热久久精品无码_国产99在线a视频国产高清乱码中文_日韩亚洲和欧洲码_忘忧草WWW日本社区_91福利免费在线av观看一区二区三区,网友自拍区视频精品

      • U-shaped Coriolis Mass Flowmeter
      • V-shaped Coriolis Mass Flowmeter
      • Corrosion Resistant Coriolis Mass Flowmeter
      • Miniature Coriolis Mass Flowmeter
      Coriolis Mass Flowmeter
      • Applicable Medium
        Liquid, typical applications in industries such as petroleum, oil and gas, chemical, etc
      • Not applicable medium
        solid
      • Product Introduction
        The Coriolis mass flowmeter is a new type of high-precision flow and density measurement instrument developed by our company based on the Coriolis force principle and multivariate digital processing measurement technology. It can directly measure the mass flow rate of the medium passing through the flowmeter, as well as measure the density of the medium and indirectly measure the temperature of the medium.

      Working principle

      When a particle located inside a tube that rotates with P as the fixed point (rotation center) moves towards or away from the rotation center, an inertial force will be generated, as shown in Figure 1.1;

      圖片1.png

      The particle with a mass of δ m in Figure 1.1 moves to the right inside the pipeline at a constant speed υ, while the pipeline rotates around a fixed point P at an angular velocity ω. At this point, this particle will obtain two acceleration components: (1) normal acceleration α r (centripetal acceleration), which is equal to ω 2r and points towards the P axis.

      (2) Tangential acceleration α t (Coriolis acceleration), with a value equal to 2 Ωυ and a direction perpendicular to α r,

      The force generated by tangential acceleration is called Coriolis force, and its magnitude is equal to Fc=2 Ωυδ m. Fluid in the diagram

      δ m=ρ A × Δ X, therefore the Coriolis force can be expressed as: Δ Fc=2 Ωυ× δ m=2 Ω× υ× ρ× A × Δ X

      =2ω×δqm×ΔX

      In the formula, A is the cross-sectional area of the pipeline, δ qm=δ dm/dt=υρ A. For a specific rotating pipeline, its frequency characteristics are constant,

      Δ Fc depends only on δ qm. Therefore, direct or indirect measurement of Coriolis force can be used to measure mass flow rate. The Coriolis mass flowmeter works based on the above principle.


      Product Features

      It can directly measure the mass flow rate of fluid in a closed pipeline and can be used as a high-precision mass flowmeter (which is of great significance for energy measurement and production process control such as chemical reactions);

      It can directly measure the working density of the medium and can be used as a high-precision online density meter;

      MVDTM measurement technology (multivariate digital processing system) is adopted. The application of MVDTM technology enhances signal filtering, greatly improves the sensitivity and accuracy of signal measurement, accelerates system response time, and makes measurement more reliable;

      The adoption of MVDTM measurement technology makes the system composition more flexible and convenient. In many cases, MVD modules and sensors can form a complete flow measurement system without the need to configure a flow converter. For example, CNG, LNG refueling systems, quantitative control systems, flow or density unit parameter measurement systems, etc;

      High measurement accuracy, mass flow measurement accuracy can reach 0.1%~0.2%, and density measurement resolution can reach 0.001g/cm 3; Temperature measurement error is less than 0.5 ℃;

      Implementation of density and temperature measurement functions, which can derive medium concentration measurement functions (for two-component media);

      The installation requirements are not high (there are no requirements for upstream and downstream straight pipe sections), and the sensor has no mechanical movable parts and operates reliably;

      Wide applicability, the same sensor can be used for multiple media.

      Technical parameter

      Reference Range Table for Coriolis Mass Flow Meter

      Model

      Nominal Diameter

      Flow range

      MFS-01

      01

      0.001-0.01t/h

      MFS-02

      02

      0.004-0.08t/h

      MFU-003

      3

      0.009t/h~0.18t/h

      MFU-006

      6

      0.048t/h~0.96t/h

      MFU-010

      10

      0.1t/h~2.1t/h

      MFU-015

      15

      0.25t/h~4.5t/h

      MFU-020

      20

      0.36t/h~7.2t/h

      MFU-025

      25

      0.6t/h~12t/h

      MFU-032

      32

      1.05t/h~21t/h

      MFU-040

      40

      1.8t/h~36t/h

      MFU-050

      50

      3t/h~60t/h

      MFU-080

      80

      10t/h~200t/h

      MFU-100A

      100

      14t/h~280t/h

      MFU-100B

      100

      16t/h~320t/h

      MFU-150

      150

      24t/h~480t/h

      MFU-200

      200

      45t/h~900t/h

      Basic parameters of MFU series Coriolis mass flowmeter

      Pipeline diameter

      DN3-DN200

      Flow measurement accuracy

      0.1%、0.15%、0.2%

      Repeatability

      0.05%

      Density measurement range

      0<p<5g/cm3

      Density measurement accuracy

      ±0.001g/cm3

      Temperature measurement range

      -200℃~350℃

      Temperature measurement accuracy

      ±1℃

      Temperature of the measured medium

      -50℃~300℃

      Applicable ambient temperature

      -30~70℃

      Measurement tube material

      316L、Hastelloy alloy

      Working pressure

      Conventional 4Mpa, high pressure can be specially customized

      Explosion proof grade

      Exd[ib]IICT1~T6Gb

      Protection grade

      IP67

      Output signal

      4-20mA、0-10KHZ frequency signal, pulse equivalent signal、RS485、HART

      Basic parameters of MFV micro bending Coriolis mass flowmeter

      Pipeline diameter

      DN3-DN100

      Flow measurement accuracy

      0.1%-0.2%

      Density measurement range

      0<p<5g/cm3

      Density measurement accuracy

      ±0.001g/cm3

      Temperature measurement range

      -200~350℃

      Temperature measurement accuracy

      ±1℃

      Temperature of the measured medium

      -50℃~200℃

      High temperature customizable

      Applicable ambient temperature

      -30~70℃

      Measurement tube material

      316L,Hastelloy, tantalum

      Repeatability

      0.05%

      Explosion proof grade

      Exd[ib]IICT1-T6Gb

      Protection grade

      IP67

      Working pressure

      Conventional 4MPa, high pressure can be specially customized

      Output signal

      4-20mA、0-10KHZ frequency signal, pulse equivalent signal、RS485、HART

      Basic parameters of MFC low-temperature Coriolis mass flowmeter

      Pipeline diameter

      DN3-DN200

      Quality measurement accuracy

      0.1%、0.15%、0.2%、0.5%

      Repeatability

      0.05%

      Density measurement range

      0<p<5g/cm3

      Density measurement accuracy

      ±0.001g/cm3

      Temperature measurement range

      -200℃~350℃

      Temperature measurement accuracy

      ±1℃

      Temperature of the measured medium

      -200℃~100℃

      Applicable ambient temperature

      -30~70℃

      Measurement tube material

      316L

      Working pressure

      Conventional 4Mpa, high pressure can be specially customized

      Explosion proof grade

      Exd[ib]IICT1~T6Gb

      Protection grade

      IP67

      Output signal

      4-20mA、0-10KHZ frequency signal, pulse equivalent signal、RS485、HART

      Basic parameters of MFS miniature Coriolis mass flowmeter

      Pipeline diameter

      DN1、DN2

      Flow measurement accuracy

      0.1%-0.2%

      Density measurement range

      0<p<5g/cm3

      Density measurement accuracy

      ±0.001g/cm3

      Temperature measurement range

      -200~350℃

      Temperature measurement accuracy

      ±1℃

      Temperature of the measured medium

      -50℃~150℃

      Applicable ambient temperature

      -30~70℃

      Measurement tube material

      316L,哈氏合金

      Repeatability

      0.05%

      Explosion proof grade

      Exd[ib]IICT1-T6Gb

      Protection grade

      IP67

      Working pressure

      Conventional 4Mpa, high pressure can be specially customized

      Output signal

      4-20mA、0-10KHZ frequency signal, pulse equivalent signal、RS485、HART