免费观看B站60帧的视频软件_一线二线三线99热热久久精品无码_国产99在线a视频国产高清乱码中文_日韩亚洲和欧洲码_忘忧草WWW日本社区_91福利免费在线av观看一区二区三区,网友自拍区视频精品

      • Differential Pressure Transmitter
      • Differential Pressure Transmitter
      • Differential Pressure Transmitter
      • Differential Pressure Transmitter
      Differential Pressure Transmitter
      • Applicable Medium
        Gas, liquid
      • Not applicable medium
        solid
      • Product Introduction
        This product is widely used in water plants, oil refineries, sewage treatment plants, building materials, light industry, machinery and other industrial fields to realize the measurement of liquid, gas, and vapor pressure.

      Working principle

      The Intelligent Differential Pressure Transmitter is an advanced instrument for measuring fluid differential pressure. Differential pressure refers to the difference between the pressure at two different positions, which can convert the differential pressure into a standard electrical signal output and provide a variety of functions and intelligent features.


      The two pressures of the measured medium enter the high and low pressure chambers, act on the isolation diaphragms on both sides of the delta element, and are transmitted to both sides of the measurement diaphragm through the isolation sheet and the filling liquid in the element. The electrodes on the measuring diaphragm and the insulating plates on both sides each form a capacitor.

      When the pressures on both sides are inconsistent, the measurement diaphragm will be displaced. The displacement is proportional to the pressure difference. Therefore, the capacitances on both sides are not equal. Through the oscillation and demodulation link, it is converted into a signal proportional to the pressure. The working principle of pressure transmitter and absolute pressure transmitter is the same as that of differential pressure transmitter, but the difference is that the pressure in the low-pressure chamber is atmospheric pressure or vacuum.

      The A/D converter converts the current of the demodulator into a digital signal, the value of which is used by the microprocessor to determine the input pressure value. The microprocessor controls the work of the transmitter. In addition, it performs sensor linearization. Reset the measurement range. Engineering unit conversion, damping, square extraction, sensor fine-tuning and other operations, as well as diagnosis and digital communication.


      Product Features

      ●Intelligent electronic components consist of only one piece.

      ●The range ratio is 15:1 or 10:1.

      ●0-0.6-0-42000KPa.

      ●Press the local key to adjust the range and zero point.

      ●It can update the existing TY-1151 (including 1151) various analog transmitters as smart meters.

      ●Comply with HART protocol, HART communicators 268 and 275 can be used for two-way communication with this smart meter without interrupting the output signal.

      ● Two-way communication with the host computer in the distributed control system using HART protocol.

      ●With self-diagnosis and remote diagnosis functions.

      ●With EEPROM, you are not afraid of losing data after power failure.


      Technical Parameters

      Performance parameter


      Measuring medium

      Gas, steam, liquid

      Precision

      ±0.075%, ±0.1%, ±0.2% (including linearity from zero, hysteresis and repeatability)

      stability

      ±0.1%/3 years

      power supply

      10~36V DC (24V DC recommended)

      Reference accuracy of 

      range adjustment

      If TD>10 (TD=maximum range/adjustment range), 

      then: ±(0.075×TD)%

      Ambient temperature

      -40℃ ~85℃

      Measure the temperature 

      of the medium

      -40℃~120℃

      Storage temperature

      -40℃ ~85℃

      show

      LCD、OLED

      The display shows the

       temperature of the module

      -20℃~70℃(LCD)、-40℃~80℃(OLED)

      Physical parameter


      Measuring diaphragm

      316L, Tantalum, Hastelloy C, Monel

      Process connection

      Stainless steel 304, 316L

      Nuts and bolts

      Carbon steel galvanized, stainless steel

      Filling fluid

      Silicone oil, fluorine oil, etc.

      Sealing ring

      Nitrile rubber, fluorine rubber, polytetrafluoroethylene

      Transmitter housing

      Aluminum alloy material, sprayed with epoxy resin on the outside

      Shell seal

      Nitrile rubber

      Nameplate

      Stainless steel 304

      weight

      2.8kg (None: mounting bracket, process connection)

      Shell protection level

      IP67

      Explosion-proof grade

      Exd Ⅱ CT6 Gb、Exia Ⅱ CT6 Ga

      Power supply and load 

      conditions


      The power supply voltage is

      24V DC R≤(Us-10V)/ImaxΩ where Imax=21 mA

      Maximum power supply 

      voltage

      36V DC

      Minimum power supply 

      voltage

      10V DC

      Digital communication 

      load range

      250~600Ω

      Function parameter


      Range limit

      Within the upper and lower limits of the range, it can be set arbitrarily, as long as the calibration range is greater than or equal to the set range.

      It is recommended to select a range with the lowest possible turndown ratio to optimize performance.

      Influence of installation location

      The change of the installation position will affect the zero position, which can be corrected by zero adjustment, and there is no influence on the range.

      Output

      Two-wire system 4-20mA, in line with NAMIR NE43 specification, superimposed digital signal (Hart protocol)

      Output signal limit

      Imin (minimum): 3.9mA Imax (maximum) = 21.0mA

      Alarm current

      Low report mode (minimum): 3.9mA High report mode (maximum): 21mA (user can preset)

      Alarm current default 

      setting

      High report mode

      Fault warning

      If the sensor or circuit fails, the automatic diagnosis function will automatically output 22.0mA

      Response time

      The damping constant of the amplifier component is 0.1s; the time constant of the sensor is 0.1~1.6s, depending on the range and the range ratio.

      The additional adjustable time constant is: 0~100s

      Preheat time

      <15s


    1. Home
    2. Tel
    3. Email
    4. Top