免费观看B站60帧的视频软件_一线二线三线99热热久久精品无码_国产99在线a视频国产高清乱码中文_日韩亚洲和欧洲码_忘忧草WWW日本社区_91福利免费在线av观看一区二区三区,网友自拍区视频精品

      • COD Water Quality Online Analyzer
      COD Water Quality Online Analyzer
      • Applicable Medium
        water
      • Not applicable medium
        gas
      • Product Introduction
        Chemical oxygen demand (COD) is a chemical method used to measure the amount of reducing substances that need to be oxidized in a water sample. Under certain conditions, the amount of oxidant consumed to oxidize the reducing substances in 1 liter of water sample is used as an indicator to convert it into milligrams of oxygen required per liter of water sample after oxidation, expressed in mg/L

      Working principle

      Heating a mixture of water sample, potassium dichromate digestion solution, silver sulfate solution (silver sulfate as a catalyst can more effectively oxidize linear fatty compounds), and concentrated sulfuric acid to 170 ℃, the color of the organic matter in the dichromate ion oxidation solution will change. The analyzer detects this color change and converts it into COD value output. The amount of dichromate ions consumed is equivalent to the amount of oxidizable organic matter.

      Product Features

      1. The digestion colorimetric process of the instrument is completed in one, with a simple and reliable structure, reducing the possibility of errors.

      2. Adopting imported modified polytetrafluoroethylene transparent hose with a diameter greater than 1.5mm, reducing the probability of particle blockage in water samples.

      3. It can automatically clean the sampling pipeline to prevent the formation of algae or biofilm.

      4. After abnormal reset and power failure, the instrument will automatically discharge residual reactants and restore working status.

      5. Low failure rate, minimal maintenance, and low reagent consumption.

      6. The intelligent fault self diagnosis function, alarm prompt, instrument management and maintenance are very convenient.

      7. Adopting multi-channel valves, it has strong anti-corrosion performance, long service life, and is safe and reliable.

      Technical Parameter

      Model No.YK-DH310C1
      Methodological basisNational Standard GB11914-89 Water Quality - Determination of Chemical Oxygen Consumption - Dichromate Method
      Measurement range10~2000mg/L COD
      AccuracyDisplay value error ≤ ±10%
      repeatability error≤±10%
      measuring cycleMinimum measurement period is 40min, according to the actual water samples can be modified at any time from 5~120min.
      sampling periodTime interval (20~9999min arbitrary adjustable) and whole point measurement mode
      correctionSensitivity and zero calibration can be performed at regular intervals.
      calibration period1~99 days any interval any time adjustable
      Maintenance CycleUsually once a month for about 30 minutes
      analog output1 channel 4~20mA output (optional 2 channels 4~20mA output)
      signal interfaceRS232 or RS485
      Switching volumeOptional 1-6 relay outputs, 220VAC/2A capacity
      Comparison of actual water samplesTolerance ≤±10%
      MTBF≥720h/session
      Environmental requirementsRecommended temperature +5~28℃; humidity ≤90% (no condensation)
      SizeH 1430 x W 500 x D 403 (mm) .
      Power sourceAC220±10%V, 50±10%Hz, 5A
      OthersAbnormal alarms and power failures do not result in data loss. Touch screen display and command input;
      Abnormal reset and power failure, the instrument automatically discharges the residual reactants in the apparatus and automatically restores the working state
      typical applicationMunicipal sewage treatment plant import and export water quality online monitoring, industrial pollution source wastewater online monitoring, industrial process
      Online monitoring of water use, etc.


    1. Home
    2. Tel
    3. Email
    4. Top