免费观看B站60帧的视频软件_一线二线三线99热热久久精品无码_国产99在线a视频国产高清乱码中文_日韩亚洲和欧洲码_忘忧草WWW日本社区_91福利免费在线av观看一区二区三区,网友自拍区视频精品

      • Turbidimeter
      Turbidimeter
      • Applicable Medium
        Water
      • Not applicable medium
        Gas
      • Product Introduction
        Turbidity meter is an online analytical instrument designed to measure the turbidity of water in municipal or industrial wastewater treatment processes. It can be applied to changes in turbidity during biochemical treatment processes, providing continuous and accurate measurement results.

      Working principle

      The turbidity meter photoelectric sensor consists of a light source, lens, photoelectric element, etc. When light passes through the measured liquid sample, scattered light in a 90 ° direction with the incident light acts on the photoelectric element, generating an electrical signal that varies with turbidity. This signal is sent to the signal processor together with the reference signal. The signal processor, with integrated circuits as its core, forms a stable electronic circuit that amplifies, filters, performs operations, compensates, and other processes on the signal, making it linearly related to the turbidity of the measured liquid sample throughout the entire measurement range.

      Product Features

      1. The menu structure is easy to operate and displayed in both Chinese and English;

      2. Multi parameter display on the same screen;

      3. Bubble suppression system eliminates bubbles;

      4. Convenient calibration, fast verification, and online calibration;

      5. Historical curve and digital recorder function;

      6. Multiple signal outputs and alarm functions;

      7. Good repeatability, unaffected by sample flow rate and pressure.

      Technical Parameter

      model

      YK-ZDYG-2088Y/T

      Range

      0-5NTU, 0-10NTU, 0-20NTU, 0-100NTU, 0-200NTU, 0-200NTU are specified when ordering

      Accuracy

      <FS (full scale) ± 2%

      Reproducibility

      <FS±1%

      resolving power

      0.001NTU/0.01NTU/0.1NTU

      Sampling quantity

      200ml continuous

      Adapt to temperature

      4~40

      relative humidity

      <70%RH

      supply voltage

      200~240V,50HZ

      power waste

      <25W

      Display partial external dimensions

      146 (length) × 146 (width) × 138 (depth)

      Hole size

      138×138 mm

      Sensor size

      340 (length) x 280 (width) x 160 (depth) mm

      Water tank size

      180 (length) x 160 (width) x 80 (depth) mm

      Weight

      15kg

      Regular use

      Mostly used in situations where there are fewer impurities in the water quality

      application area

      Tap water, power plants, sewage treatment plants, pharmaceutical factories, hospitals 


    1. Home
    2. Tel
    3. Email
    4. Top